Article ID : 00169728 / Last Modified : 02/01/2017

The DSEE HX or DSD Remastering indicator on the TA-ZH1ES headphone amplifier is not turning on even when it is set to ON.

Applicable Products and Categories of This Article

IMPORTANT: This article applies only to specific products and/or operating systems. Check the Applicable Products and Categories section of this article before starting these steps.

Check the following if the DSEE HX or DSD Remastering indicator is not lighting up even when it is set to ON.

  • When the DSEE HX indicator does not light up even when DSEE HX is set to ON.

    DSEE HX indicator

    • A: DSEE HX indicator

      If an incompatible input signal is received and DSEE HX is set to ON, the DSEE HX indicator lights up and turns off immediately. DSEE HX works only with the following formats:

     

    Sampling frequency

    Bit depth

    PCM (Pulse Code Modulation)

    32kHz 16, 24, 32
    44.1kHz 16, 24, 32
    48kHz 16, 24, 32
    88.2kHz 16, 24
    96kHz 16, 24
    176.4kHz 16, 24
    192kHz 16, 24
    352.8kHz 16, 24
    384kHz 16, 24
    705.6kHz 16, 24
    768kHz 16, 24
  • When the DSD RE. indicator does not light up even though DSD Remastering is set to ON.

    DSD RE Indicator

    B: DSD RE. indicator

    DSD Remastering is only available with the PCM format signals. DSD Remastering does not work on the DSD format signals.